Rapid Fire Design PTY LTD

Rapid Fire Design PTY LTD SPECIALISING IN WET FIRE PROTECTION Looking for new challenges Darryl moved his family to Australia where he has worked for 11 years.

Darryl Friar commenced his career 1994 in New Zealand as a Fire Systems Designer and then proceeded to broaden his skill set by working as a Estimator and then Project Manager. This experience lead him into a Senior Role as a Consultant for four years with one of New Zealand's leading Fire Protection Consultancy Firms. Darryl’s experience is unique and sets him apart from other designers. He is a

specialist in his field who uses his extensive knowledge and experience in providing the best solutions for all Wet Fire Protection needs.

19/12/2025

We extend our warmest wishes for a joyous Christmas, a peaceful holiday season, and a prosperous new year.

Freezer's and Cool rooms 4 deg C or less require a sprinkler called a Dry Drop or Dry Barrel Sprinkler. This type of Spr...
13/12/2024

Freezer's and Cool rooms 4 deg C or less require a sprinkler called a Dry Drop or Dry Barrel Sprinkler.
This type of Sprinkler doesn't allow the water to enter the pipe until there bulb (element) pops. If we used standard sprinklers the water would freeze in the pipe behind the sprinkler.
Often in supermarkets in the back of house area they put there chillers and freezers under the mezzanine (usually offices/lunch room on top) to utilise space.
Often they will design it so that the refrigeration panel is hard too or as close to the slab above as possible.
If Sidewall dry drops cant be used, the ceiling panel needs to be dropped to allow for the installation of the dry drop sprinkler.

Spotting these little issues early on in the design development stage is this key. There is no point waiting for the contractor to tell them as they are going to construction that it is not going to work.

Explaining to architects about the 1m clearance required in a fire stair becomes very repetitive. A drawing/picture is w...
13/12/2024

Explaining to architects about the 1m clearance required in a fire stair becomes very repetitive. A drawing/picture is worth a 1000 words.

Combined Hydrant and Sprinkler System.Break Tanks & Diesel Pump Set. Residential Apartments near the beach, basement car...
13/12/2024

Combined Hydrant and Sprinkler System.
Break Tanks & Diesel Pump Set.
Residential Apartments near the beach, basement car park.
First 3 floors Designed and Fabbed, Five more floors to go.

This Warehouse required concept design and is now progressing to Building License. 13,000 sq m. 2 Storey Office, Diesel ...
13/12/2024

This Warehouse required concept design and is now progressing to Building License. 13,000 sq m. 2 Storey Office, Diesel Pump Set, 504 kl Water Tank.

This one is 2 Warehouse sharing combined Water Supplies.Warehouse 1 is 20,000 sqm and has Five 2 storey offices.K22.4 (3...
13/12/2024

This one is 2 Warehouse sharing combined Water Supplies.
Warehouse 1 is 20,000 sqm and has Five 2 storey offices.
K22.4 (32m) sprinklers @ 350 kPa.
Warehouse 2 is 7,260 sqm and has One 2 storey office.
K16.8 (24m) sprinklers @ 350 kPa.
Four systems and 532 kl Fire Tank.
System 1 has just finished Fabrication.

11,000 sq m Warehouse halfway through construction.System 1 Fabricated, System 2 to go.K16.8 (24m) ESFR, Diesel Pump Set...
13/12/2024

11,000 sq m Warehouse halfway through construction.
System 1 Fabricated, System 2 to go.
K16.8 (24m) ESFR, Diesel Pump Set & 395 kl Fire Tank.

Small Warehouse at Brisbane Airport well underway.K25.2 (36m) @ 410 kPa. Diesel Pump Set, 650 kl Fire Tank.
13/12/2024

Small Warehouse at Brisbane Airport well underway.
K25.2 (36m) @ 410 kPa. Diesel Pump Set, 650 kl Fire Tank.

Building License drawings done for a New Warehouse. K16.8 (24m) Sprinklers in 4200 sq m Warehouse. Two Storey office and...
13/12/2024

Building License drawings done for a New Warehouse.
K16.8 (24m) Sprinklers in 4200 sq m Warehouse.
Two Storey office and Small Canopy.

Preliminary Consultant Design Started on a Eight Storey Student Accommodation building.Combined System with Pumps & Tank...
13/12/2024

Preliminary Consultant Design Started on a Eight Storey Student Accommodation building.
Combined System with Pumps & Tanks, OH2 in Basement Carpark, OH1 for Ground Floor, Residential Floors 1-7 then OH1 for Gym and Pool on Roof.

Rapid Fire Design proudly supports The Emergency Service Volunteers
03/12/2024

Rapid Fire Design proudly supports The Emergency Service Volunteers

Address

Perth, WA
6122

Opening Hours

Monday 7am - 5am
Tuesday 7am - 5am
Wednesday 7am - 5am
Thursday 7am - 5am
Friday 7am - 5am
Saturday 7am - 12pm

Telephone

+61455208783

Alerts

Be the first to know and let us send you an email when Rapid Fire Design PTY LTD posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Rapid Fire Design PTY LTD:

Share