2026/10/08
🕒 960 hours. 85 °C. 85 % humidity.
That is the 85/85 damp-heat test — and it is where a lot of insulation failures really begin.
We put a hydrolysis-resistant BMC through four stages of it, in two wall thicknesses (3.0 mm and 1.5 mm), and tracked five properties the whole way:
✅ Flexural strength: 104 % / 97 % retained
✅ Surface resistance: ≥10¹¹ Ω at every stage
⚠️ Impact strength: −30 % / −36 %
The full dataset — including the part most datasheets leave out — is in the article.
Specifying insulation for humid, condensing or outdoor service? Let's talk.
📧 [email protected]
960-hour 85/85 aging data for hydrolysis-resistant BMC: flexural retained 104 %/97 %, tensile −7 %, impact −30 %/−36 %, surface resistance ≥10¹¹ Ω throughout.