06/05/2023
£10000 or £100?? I know which bill I’d rather have!
The customer was quoted almost £10000 for a replacement boiler by his engineer due to water leaking in the casing and wanted a second quote.….
After a very short investigation I found the condense drain pipe was blocked causing condensation to build up and leak out of the baffle door seal into the bottom of the casing!!
No new boiler needed just unblocked the pipe and gave it and the boiler a good clean up
£100 later the customer was extremely happy to say the least!!!! Boiler is now running faultlessly again.
New baffle door seal ordered and will be fitted on the service in a couple of weeks!
Sometimes it pays to get a second opinion!