Agni Surksha

Agni Surksha Single Step Destination for all kind of Fire Safety Solutions our Fire Extinguisher Inspections help reduce the risk of damage to your facility

We offer a complete bouquet of Services to our Clients which range from surveys to analysis till design and engineering. Our Services ensure that your facility is properly equipped to face a fire emergency and compliant with all applicable regulatory code.

06/01/2016

BIS code for PPE's & safety equipment.
Helmet-2925
Safety shoes - 15298
Ear plugs - 9167
Hand gloves - 6994
Goggles - 5983
Full body harness - 3521
Welding face shield 8521
Grinding wheel - 1991
Flash back arrested 11006
Fire extinguisher - 15683
Scaffolding - 3696
Ladder - 7010.

_________________________
To calculate the SWL in kilograms of FSWR square the rope diameter (D) in millimetres (mm) and multiply by 8.
Formula: SWL (kg) = D2(mm) x 8
For example:
Rope dia (D) = 12 mm
SWL(kg) =D2 (mm)x8
= D (mm) x D (mm) x 8
= 12 x 12 x 8
= 1152 kg SWL (t) = 1.15 tonnes
The above equation can be reversed to calculate the diameter (D) in millimetres of FSWR needed to lift a given load. To do this, divide the load (L) in kilograms by 8 and find the square root of the result.
Formula: D(mm) = √L(kg) 8
For example:
Load = 1152 kg
D (mm) = √1152 ÷ 8 = √144
= 12 (mm)
Therefore a FSWR sling of at least 12 mm in diameter is required to lift a 1152 kg load for a straight lift.
_______________________

Factory act?
Sec.’6’ Registration of a factory
Sec.’11’ Cleanliness
Sec.’13’ Ventilation and temperature
Sec.’17’ Lighting
Sec.’18,19’ Drinking water and sanitary
Sec.’23’ Employment of young person on dangerous mechanical
Sec.’28’ Hoist and lifts
Sec.’29’ Lifting machines and tackles
Sec.35’ protection of eyes
Sec.’36’ Precaution against danger furmes
Sec.’36(A)’ Use of portable electric light
Sec.’38’ Protection in case of fire
Sec.’40(A)’ Maintenance of building
Sec.40(B)’ Safety officers duty
Sec.’45’ First aid boxes
Sec.’111’ Obligation of workers

18/11/2015
08/11/2015

Surprising but feeling satisfied that Fire Safety awareness is being spread via tv shows also..
Thanks to StarPlus for this special show

Recently, installed in a warehouse
07/11/2015

Recently, installed in a warehouse

Address

Delhi

Website

Alerts

Be the first to know and let us send you an email when Agni Surksha posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Agni Surksha:

Share