LEW - Licensed Electrical Workers

LEW - Licensed Electrical Workers A Singapore based electrical consultancy group, we provide professional engineering and LEW services to meet EMA of Singapore requirement.

A Singapore based electrical engineering consultancy group, we provide electrical design and installation consultancy, thermal scanning services and LEW certification.

14/05/2022

Looking for capable contractor for writing work in condo unit. Contact me in messenger please. Thanks.

Have a HDB shop house and still at 40A supply? Thinking to upgrade to 63A for more option for your unit? Message us for ...
18/01/2021

Have a HDB shop house and still at 40A supply? Thinking to upgrade to 63A for more option for your unit? Message us for details.

Earthing cables labelling.  Don’t use acronyms. M-E can be Main Earth or Metal Earth.
27/07/2020

Earthing cables labelling.
Don’t use acronyms. M-E can be Main Earth or Metal Earth.

According to the Code, if you use brown color coded cables for Live, all brown cables are to be labelled L1 or L2 or L3.
27/07/2020

According to the Code, if you use brown color coded cables for Live, all brown cables are to be labelled L1 or L2 or L3.

Attended a SP Turn-On Inspection of an industrial unit, because owner has had electrical woring experience before so he ...
27/07/2020

Attended a SP Turn-On Inspection of an industrial unit, because owner has had electrical woring experience before so he did his own unit’s wiring.
However, Main DB has incomer using 16sq-mm for 63A 3-ph which is correct. But outgoing he uses only 10sq-mm cable. Thus such obvious mismatch is a no-no.

Your appointed LEW must go through one or even more rounds of internal inspection and testing to ensure SP Turn-ON goes well, first time.

Need a Lightning Protection System drawing? We can carry out site survey and develop drawing plan with LEW endorsement. ...
20/06/2020

Need a Lightning Protection System drawing? We can carry out site survey and develop drawing plan with LEW endorsement.

Drop us a message to discuss. ;)

Good old boring Main Distribution Board should now get a make over with this small and powerful device added. With perma...
31/10/2019

Good old boring Main Distribution Board should now get a make over with this small and powerful device added.

With permanent IR camera looking over the busbars you can predict the next PM through feedback system to FM.

Improper heater wiring caused boy's death while showering.Although in Singapore, home electrical circuit is not required...
19/10/2018

Improper heater wiring caused boy's death while showering.

Although in Singapore, home electrical circuit is not required to be inspected by LEW by regulation, it is good to carry out ELCB strip testing on your own regularly.

It is as simple and safe as pressing the trip button on the ELCB to Ensure the ELCB trips and working. If it doesn’t trip, it is faulty and need to be replaced by an electrician.

In this case poor workmanship of improper tightening of both neutral and earth terminal causes heat generation, and melted both terminals and fused together. When that happen, returning current path is leaked to earth stated in report as 0.95A.

A working ELCB would have trip at 0.03A.

So start your own trip test now to check your home electrical safety by pressing the ELCB strip button to see if your ELCB is working or not.

The improper wiring of a water heater to a three-pin plug by workers unlicensed to do electrical work after a Housing Board upgrading programme was behind the death of a 15-year-old boy, who was electrocuted while showering.. Read more at straitstimes.com.

How a Circuit Breaker Works in Slow Motion
09/10/2018

How a Circuit Breaker Works in Slow Motion

If you've ever wondered how that pesky circuit breaker Works inside when your lights turn off, then this is the episode you need to watch. I open up a househ...

Thermal Scan conducted regularly and annually for buildings under our charge.
29/09/2018

Thermal Scan conducted regularly and annually for buildings under our charge.