Daniel Gaydos with Climate Masters inc.

Daniel Gaydos with Climate Masters inc. I have been working with Climate Masters for 20 years. Service Plus since 1967

I have developed pretty good set of skills within this trade and I feel like it’s beneficial to share some of my experiences, tips, and/or tricks.
*Service Manager*

06/19/2026

Clear those drains and go on add some condensate safety switches!
Why in the world some of these contractors out here choose to install equipment without safeties blows my mind.

06/17/2026

Common sense… Not so common.

There's more to a drain system than just the drain line.
06/15/2026

There's more to a drain system than just the drain line.

06/15/2026

Check out your filters!

06/14/2026

🚨 Your AC Return Size Matters!
Most homes are starving their system because the return is too small.
The pros’ rule: 200 square inches of return area per ton.
✅ Each 3-ton air handler needs at least 600 sq inches of total return grille area.
✅ With two 3-ton units = 1,200 sq inches total recommended.
Undersized returns = higher bills, poor cooling, frozen coils, and shorter equipment life.
Measure yours today! Comment your return grille sizes 👇 and I’ll tell you if they’re good.

06/14/2026

South Alabama homeowners: Insulate your AC condensate drain lines!
That cold drain pipe in your hot attic sweats like crazy in our humidity → drips, mold, and damage.
A little foam insulation prevents big headaches.

06/11/2026

Any HVAC Maintenance visit should have a blower inspected and cleaned.


Carrier up flow air handler with a improper filtration set up.The factory metal frame filters for Carrier air handlers a...
06/11/2026

Carrier up flow air handler with a improper filtration set up.

The factory metal frame filters for Carrier air handlers are typically washable, aluminum mesh pre-filters (frequently associated with HK/KFAFK part numbers). In up flow configurations, these filters are usually placed in a bottom-mounted rack.

Filter Sizing: The metal filter's physical dimensions (like 16"x21.5", 20"x21.5", or 13"x21.5") are specific to your exact cabinet width (024, 030, 036, 042, etc.). Always verify your unit's exact slot measurements.

DO NOT ASSUME or DO... either way, we can help!

06/10/2026
06/09/2026

The coil cleaner took one look at the evaporator and asked for hazard pay.

Address

30850 Jay Drive
Daphne, AL
36527

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm

Alerts

Be the first to know and let us send you an email when Daniel Gaydos with Climate Masters inc. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Daniel Gaydos with Climate Masters inc.:

Share