Put a float switch in place of the piping for the overflow or secondary drain. Who wants a pan full of water in the atti...
03/11/2026

Put a float switch in place of the piping for the overflow or secondary drain. Who wants a pan full of water in the attic overhead when there is no reason for it ? ๐Ÿ’›๐Ÿ’

AC blowing room temperature air, attic coil dripping slightly โ€” what should I check before calling a tech?
Iโ€™m trying to diagnose an AC issue myself before calling an HVAC technician.

Hereโ€™s whatโ€™s happening:

The AC is running and blowing air through the vents, but the air is not cold. It feels like regular room-temperature air, almost like a fan.

The thermostat is set to 65ยฐF, but the house never cools down.

The evaporator coil unit in the attic is dripping a tiny amount of water (maybe a drop every few seconds). Nothing extreme, just a very small drip.

The outdoor condenser unit is running, but it does look a bit dirty. The last time I washed the outside coils was probably about 3 years ago.

A few questions:

Is the small dripping from the attic coil normal, or could that indicate something like freezing/defrosting?

Could dirty condenser coils alone cause the system to blow non-cold air, or would it usually still be somewhat cool?

What basic things should I check myself before calling an HVAC technician?

Are there signs that this could be low refrigerant, frozen coil, capacitor issue, or compressor not engaging?

For context:

Airflow from vents seems normal/strong.

It just isnโ€™t cold at all.

System otherwise sounds like itโ€™s running normally.

Any troubleshooting steps I can safely check would be appreciated.

Beautiful day to be inside and insulate duct work out of the rain.... ๐Ÿ’›๐Ÿ’
03/11/2026

Beautiful day to be inside and insulate duct work out of the rain.... ๐Ÿ’›๐Ÿ’

That's why we have books. โค๏ธโœ๏ธ๐Ÿ‡บ๐Ÿ‡ธ
02/27/2026

That's why we have books. โค๏ธโœ๏ธ๐Ÿ‡บ๐Ÿ‡ธ

I say bigger header because of the span he says it's enough what does the group think it's jus...

I know my engineer would say bigger header.

No vent should be between the coil and the trap. Install a float switch on the secondary drain. โค๏ธโœ๏ธ๐Ÿ‡บ๐Ÿ‡ธ
02/27/2026

No vent should be between the coil and the trap. Install a float switch on the secondary drain. โค๏ธโœ๏ธ๐Ÿ‡บ๐Ÿ‡ธ

3 year old gas furnace burning pvc pipe

Smelled burning plastic in the middle of the night and realized it was coming from the furnace in the attic. Turned it off and this morning saw the pvc pipes coming up are burning/melting. I have hvac coming tomorrow morning but just found the original installers info. If this is an install issue on a 3 year old house, should I use the same company or get someone else thatโ€™s more reliable.

Community Bank I wonder how well the AC and heat work when you bury the unit in mulch. You need a landscaper who cares -...
02/27/2026

Community Bank I wonder how well the AC and heat work when you bury the unit in mulch. You need a landscaper who cares - that one doesn't. ๐Ÿ‡บ๐Ÿ‡ธโœ๏ธโค๏ธ

Here's one that took some thinking. This very popular contractor in Jackson Tennessee thought it a good idea to try and ...
02/10/2026

Here's one that took some thinking. This very popular contractor in Jackson Tennessee thought it a good idea to try and control the climate on both floors with one unit. First screwup.
So I disconnected the second floor duct system and installed a mini split heat pump. That left me with a 4 ton unit to serve the whole first floor which only needs about 2.5 tons of ac.
I considered dumping the extra air back into the return on the furnace but that would increase internal temps too much in heat and too low in cooling. So my only recourse was to dump the extra air in the enclosed attic.
Instead of abandoning the upstairs duct or removing it, I reconnected it to the supply air with a closed damper. In case the upstairs mini split quits, the supply damper can be opened and the attic damper closed to feed the upstairs.
I took static pressure readings to ensure that the downstairs duct was properly pressurized to meet specs.
There are 3 dampers. One to set back pressure to maintain correct static pressure in the supply duct system. One to control the amount dumped in the attic. One to control air flow upstairs.
All of this could have been avoided if contractors would do the job right the first time. Who cares ? ๐Ÿ’›๐Ÿ’

02/10/2026
Do not I repeat Do not install these on your HVAC system unless you have a static test performed first to determine it's...
02/09/2026

Do not I repeat Do not install these on your HVAC system unless you have a static test performed first to determine it's effects on your system first. ๐Ÿ’›๐Ÿ’

02/06/2026
02/06/2026

Address

55 Fair Oaks Place
Jackson, TN
38305

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 5pm

Telephone

+17312671881

Website

Alerts

Be the first to know and let us send you an email when Equity Enhancers posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Equity Enhancers:

Share